Ge Type Thql Thqp Circuit Breaker Panel 2 4 6 8 12 16 20 Spaces Tl240scu Tl270scu Tl412c Tl612fcu Tl812scu Tlm1212ccu Tlm1620ccu Tlm2020ccu Main Lug Load Center

Product Details
Customization: Available
Type: Power
Structure: Protection
Secured Trading Service
Gold Member Since 2022

Suppliers with verified business licenses

Audited Supplier Audited Supplier

Audited by an independent third-party inspection agency

  • Ge Type Thql Thqp Circuit Breaker Panel 2 4 6 8 12 16 20 Spaces Tl240scu Tl270scu Tl412c Tl612fcu Tl812scu Tlm1212ccu Tlm1620ccu Tlm2020ccu Main Lug Load Center
  • Ge Type Thql Thqp Circuit Breaker Panel 2 4 6 8 12 16 20 Spaces Tl240scu Tl270scu Tl412c Tl612fcu Tl812scu Tlm1212ccu Tlm1620ccu Tlm2020ccu Main Lug Load Center
  • Ge Type Thql Thqp Circuit Breaker Panel 2 4 6 8 12 16 20 Spaces Tl240scu Tl270scu Tl412c Tl612fcu Tl812scu Tlm1212ccu Tlm1620ccu Tlm2020ccu Main Lug Load Center
  • Ge Type Thql Thqp Circuit Breaker Panel 2 4 6 8 12 16 20 Spaces Tl240scu Tl270scu Tl412c Tl612fcu Tl812scu Tlm1212ccu Tlm1620ccu Tlm2020ccu Main Lug Load Center
  • Ge Type Thql Thqp Circuit Breaker Panel 2 4 6 8 12 16 20 Spaces Tl240scu Tl270scu Tl412c Tl612fcu Tl812scu Tlm1212ccu Tlm1620ccu Tlm2020ccu Main Lug Load Center
Find Similar Products

Basic Info.

Model NO.
TL
Certification
ISO9001:2000, VDE, CCC
Application Range
Power Plants
Shell Material
Steel Plate
Shell Protection Grade
IP30
Brand
Newtrend
Types
Ge Equivalent
Used Breakers
Thql, Thqp
Spaces
2 4 6 8 12 16 20
Mouting
Flush or Surface
Transport Package
Carton
Trademark
NewTrend or OEM
Origin
China

Packaging & Delivery

Package Size
50.00cm * 50.00cm * 50.00cm
Package Gross Weight
2.000kg

Product Description

GE type THQL THQP Circuit Breaker Panel 2 4 6 8 12 16 20 Spaces Tl240scu Tl270scu Tl412c Tl612fcu Tl812scu Tlm1212ccu Tlm1620ccu Tlm2020ccu Main Lug Load Center

 

Features:

♦ Flush or surface or combination, Single phase, 40-225A, 4-42 circuits.

♦ Suitable for GE Q-line circuit breakers, including also GE 1/2" THQP circuit breakers.

♦ Suitable for AC 50/60Hz, rated voltage to 110/240V, rated current 40A/70A/125A/200A/225A.

♦ Main lug line converts easily to main breaker (Convertible)

♦ Made out of high quality steel sheet and matt-finish polyester powder coated paint.

♦ Indoor and outdoor rated enclosures

♦ Straight-through main wiring

Ge Type Thql Thqp Circuit Breaker Panel 2 4 6 8 12 16 20 Spaces Tl240scu Tl270scu Tl412c Tl612fcu Tl812scu Tlm1212ccu Tlm1620ccu Tlm2020ccu Main Lug Load Center
Reference Pictures Main
Ampere
Rating
Part
Number
Max Spaces
for 1'' Breakers
Max Spaces
for 1/2" Breakers
Enclosure
Type
Type Optional Door
1P 2P 1P 2P
Ge Type Thql Thqp Circuit Breaker Panel 2 4 6 8 12 16 20 Spaces Tl240scu Tl270scu Tl412c Tl612fcu Tl812scu Tlm1212ccu Tlm1620ccu Tlm2020ccu Main Lug Load Center 40A TL240SCU 2 1 4 1 Surface Main Lug -
70A TL270SCU 2 1 4 1 Surface Main Lug -
Ge Type Thql Thqp Circuit Breaker Panel 2 4 6 8 12 16 20 Spaces Tl240scu Tl270scu Tl412c Tl612fcu Tl812scu Tlm1212ccu Tlm1620ccu Tlm2020ccu Main Lug Load Center 125A TL412C 4 2 8 3 Combination Main Lug -
Ge Type Thql Thqp Circuit Breaker Panel 2 4 6 8 12 16 20 Spaces Tl240scu Tl270scu Tl412c Tl612fcu Tl812scu Tlm1212ccu Tlm1620ccu Tlm2020ccu Main Lug Load Center TL612FCU 6 3 12 4 Flush Main Lug -
TL812FCU 8 4 16 8 Flush Main Lug -
TL612SCU 6 3 12 4 Surface Main Lug -
TL812SCU 8 4 16 8 Surface Main Lug -
Ge Type Thql Thqp Circuit Breaker Panel 2 4 6 8 12 16 20 Spaces Tl240scu Tl270scu Tl412c Tl612fcu Tl812scu Tlm1212ccu Tlm1620ccu Tlm2020ccu Main Lug Load Center TLM612FCU 6 3 12 4 Flush Convertible -
TLM812FCU 8 4 16 8 Flush Convertible -
TLM612SCU 6 3 12 4 Surface Convertible -
TLM812SCU 8 4 16 8 Surface Convertible -
Ge Type Thql Thqp Circuit Breaker Panel 2 4 6 8 12 16 20 Spaces Tl240scu Tl270scu Tl412c Tl612fcu Tl812scu Tlm1212ccu Tlm1620ccu Tlm2020ccu Main Lug Load Center TL612FCUD 6 3 12 4 Flush Main Lug with Optional Door
TL812FCUD 8 4 16 8 Flush Main Lug
TL612SCUD 6 3 12 4 Surface Main Lug
TL812SCUD 8 4 16 8 Surface Main Lug
Ge Type Thql Thqp Circuit Breaker Panel 2 4 6 8 12 16 20 Spaces Tl240scu Tl270scu Tl412c Tl612fcu Tl812scu Tlm1212ccu Tlm1620ccu Tlm2020ccu Main Lug Load Center TLM612FCUD 6 3 12 4 Flush Convertible  
TLM812FCUD 8 4 16 8 Flush Convertible
TLM612SCUD 6 3 12 4 Surface Convertible
TLM812SCUD 8 4 16 8 Surface Convertible
Ge Type Thql Thqp Circuit Breaker Panel 2 4 6 8 12 16 20 Spaces Tl240scu Tl270scu Tl412c Tl612fcu Tl812scu Tlm1212ccu Tlm1620ccu Tlm2020ccu Main Lug Load Center TLM1212CCU 12 6 24 10 Combination Convertible -
Ge Type Thql Thqp Circuit Breaker Panel 2 4 6 8 12 16 20 Spaces Tl240scu Tl270scu Tl412c Tl612fcu Tl812scu Tlm1212ccu Tlm1620ccu Tlm2020ccu Main Lug Load Center 200A TLM1620CCU 16 8 32 14 Combination Convertible -
TLM2020CCU 20 10 40 18 Combination Convertible -
Ge Type Thql Thqp Circuit Breaker Panel 2 4 6 8 12 16 20 Spaces Tl240scu Tl270scu Tl412c Tl612fcu Tl812scu Tlm1212ccu Tlm1620ccu Tlm2020ccu Main Lug Load Center
Ge Type Thql Thqp Circuit Breaker Panel 2 4 6 8 12 16 20 Spaces Tl240scu Tl270scu Tl412c Tl612fcu Tl812scu Tlm1212ccu Tlm1620ccu Tlm2020ccu Main Lug Load CenterGe Type Thql Thqp Circuit Breaker Panel 2 4 6 8 12 16 20 Spaces Tl240scu Tl270scu Tl412c Tl612fcu Tl812scu Tlm1212ccu Tlm1620ccu Tlm2020ccu Main Lug Load Center

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Send Inquiry