Customization: | Available |
---|---|
Rated Current: | 600A |
Contacts: | Spst 1no |
Still deciding? Get samples of US$ 50/Piece
Order Sample
|
Shipping Cost: | Contact the supplier about freight and estimated delivery time. |
---|
Payment Methods: |
|
---|---|
Support payments in USD |
Secure payments: | Every payment you make on Made-in-China.com is protected by the platform. |
---|
Refund policy: | Claim a refund if your order doesn't ship, is missing, or arrives with product issues. |
---|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
The SW600 DC Contactor has been designed for Direct Current loads, including motors as used on electric vehicles such as industrial trucks. Developed for both interrupted and uninterrupted loads, the SW600 is suitable for switching Resistive, Capacitive and Inductive loads.
The SW600 features Single pole Single throw, Double breaking main contacts with silver alloy tips, which are weld resistant, hard wearing and have excellent conductivity. The SW600 has M10 stud main terminals and 6.3mm spade coil connections. It can be mounted via M5 tapped holes or mounting brackets - either supplied fitted, or as separate items. Mounting can be horizontal or vertical, when vertical the M10 contact studs should point upwards. If the requirement is for downwards orientation we can adjust the contactor to compensate for this.
Model | SW600 |
Rated Current | 600A |
Contact Form | 1NO, SPST |
Contact Voltage | 6-80V DC |
Coil Voltage | 12VDC, 24VDC, or other DC voltgae less than 220VDC |
Coil Power | 11-15W |
Dielectric Voltage Strength | 50Hz 1000V AC 1min |
Volt Drop of Main Contact | <80mV |
Typical Pull-In Time | <30ms |
Typical Drop-Out Time (N/O Contacts to Open) |
<30ms |
Pull-In Voltage (Coil at 20ºC) | <66%Us |
Drop-Out Voltage (Coil at 20ºC) | 5% - 30% |
Mechanical life | 100 thousand times |
Electric life | 20 thousand times |
Circuit Diagram |